• AC High Voltage Overhead Line Contact System ANSI Glass Insulator
  • AC High Voltage Overhead Line Contact System ANSI Glass Insulator
  • AC High Voltage Overhead Line Contact System ANSI Glass Insulator
  • AC High Voltage Overhead Line Contact System ANSI Glass Insulator
  • AC High Voltage Overhead Line Contact System ANSI Glass Insulator
  • AC High Voltage Overhead Line Contact System ANSI Glass Insulator

AC High Voltage Overhead Line Contact System ANSI Glass Insulator

Application: High-voltage, Low-voltage, High-temperature
Material: Glass
Structure: AC ANSI Glass Insulator
Type: A Type Insulator
Usage: High Voltage Power Transmission, Insulation, Driving, Electrical Installation
Connection Method: Trough Type
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Hebei, China
Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 1 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
to see all verified strength labels (19)

Basic Info.

Model NO.
U
Size of Bearing Capacity
70kn~230kn
Certification
CCC, CE, ISO9001
Color
Glass
Brand
SAA
Core Rod Material
Fiber Glass Core
End Fitting Material
HDG Steel
Creepage Distance
up to 400mm
Rated Voltage System
up to 130kv
Delivery Time
3~20days
Transport Package
Carton or Plywood Case
Specification
Customers′ Requirements
Trademark
SAA
Origin
China
HS Code
8546201000
Production Capacity
1000, 000PCS/Year

Product Description

AC High Voltage Overhead Line Contact System ANSI Glass InsulatorAC High Voltage Overhead Line Contact System ANSI Glass Insulator

 

AC High Voltage Overhead Line Contact System ANSI Glass Insulator

  • Application: Suitable for transmission and distribution lines;
  • Advantage: The surface of glass insulator has high mechanical strength, and the surface is not easy to crack and the aging speed is slow, no need to measure insulation resistance during operation, low operation and maintenance cost;
  • Applicable Standard: IEC, GB, BS, ANSI, AS or Customer's requirement;

AC High Voltage Overhead Line Contact System ANSI Glass Insulator


Type

Diameter (mm)

Structural Height (mm)

Creepage Distance (mm)
 
ANSI
ANSI Level

Coupling Size (mm)

Mechanical& Electrical Strength(kN)

Tension Proof (kV)

Mechanical Impact Strength (N-m)

Low Frequency Dry Fleshover Voltage (kV)

Low Frequency Wet Fleshover Voltage (kV)

Min power Frenquency Puncture Voltage (kV)

Net Weight Per Unit(kg)
U70B/146A 255 146 320 52-3-L Type B 70 35 45 80 50 130 3.8
U100B/146A 255 146 320 52-3-H Type B 100 50 45 80 50 130 3.8
U120B/146A 255 146 320 52-5-L Type J 120 60 45 80 50 130 4.0
U120BP/146A 280 146 450 52-5 Type J 120 60 45 100 60 130 5.5
U140B/146A 255 146 320 52-5-H Type J 140 70 45 80 50 130 4.0
U160B/146A 280 146 400 52-8-L Type K 160 80 45 85 55 130 7.0
U160BP/171HA 330 171 550 52-8 Type K 160 80 45 105 65 130 9.0
U180B/146A 280 146 400 52-8-H Type K 180 90 45 85 55 130 7.0
U230B/156A 280 156 400 52-3-L Type K 230 115 45 85 55 130 7.0
U70C/146A 255 146 320 52-4-L Clevis 70 35 45 80 50 130 4.0
U100C/146A 255 146 320 52-4-H Clevis 100 50 45 80 50 130 4.0
U120C/146A 255 146 320 52-6-L Clevis 120 60 45 80 50 130 4.0
U140C/146A 255 146 320 52-6-H Clevis 140 70 45 80 50 130 4.0
U160C/146A 280 146 400 52-10-L Clevis 160 80 45 85 55 130 7.0
U180C/146A 280 146 400 52-10-H Clevis 160 90 45 85 55 130 7.0
U230C/156A 280 156 400 52-12 Clevis 180 115 45 85 55 130 7.0
Order Information:
1. Voltage grade; 2. Specified mechanical load; 3. Creepage distance; 4. Power frequency withstand voltage; 5. Lightning impulse withstand voltage; 6. Insulation distance; 7. Coupling type
Ps. Different design could be supplied as customer requirements
AC High Voltage Overhead Line Contact System ANSI Glass InsulatorAC High Voltage Overhead Line Contact System ANSI Glass InsulatorAC High Voltage Overhead Line Contact System ANSI Glass InsulatorAC High Voltage Overhead Line Contact System ANSI Glass InsulatorAC High Voltage Overhead Line Contact System ANSI Glass InsulatorAC High Voltage Overhead Line Contact System ANSI Glass InsulatorAC High Voltage Overhead Line Contact System ANSI Glass InsulatorMain Customers
AC High Voltage Overhead Line Contact System ANSI Glass InsulatorFAQ
Q:What's your main products
A:High voltage electrical equipment, including circuit breaker, arrester, insulator, load switch,etc. Low voltage electrical equipment including smart meter, time switch,etc.
Q:Do you have a catalog? Could you send me your catalogue ?
A:Yes, we have a catalogue.Please contact us, we can send you product catalog online or email.
Q:Can I get some samples?
A:Yes, sample order is available for quality check and market test.
Q:Can your factory produce according to customer's requirements?
A:Yes, we can produce different products according to customers' requirements.
Q:What's your packing standard?
A:Usually we use standard cartons for packing or according to customers' requirements
Q
:When is the delivery time?
A:We will arrange shipment within 3-20 days after your payment.

Q:Can we visit your company?
A: Yes, for sure, you are welcome to visit our company.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ANSI/ESD
OEM/ODM Availability
Yes