• 66kv Post Silicone Rubber Insulator for High Voltage Power Station
  • 66kv Post Silicone Rubber Insulator for High Voltage Power Station
  • 66kv Post Silicone Rubber Insulator for High Voltage Power Station
  • 66kv Post Silicone Rubber Insulator for High Voltage Power Station
  • 66kv Post Silicone Rubber Insulator for High Voltage Power Station
  • 66kv Post Silicone Rubber Insulator for High Voltage Power Station

66kv Post Silicone Rubber Insulator for High Voltage Power Station

Application: High-voltage, Low-voltage, High-temperature
Material: Composite Polymer
Structure: Post Insulator
Type: A Type Insulator
Usage: High Voltage Power Transmission, Insulation, Driving, Electrical Installation
Connection Method: Flange Fittings
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Hebei, China
Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 1 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
to see all verified strength labels (19)

Basic Info.

Model NO.
FZSW-66/8
Size of Bearing Capacity
8kn
Certification
CCC, CE, ISO9001
Color
Grey/Red/Customers′ Requirements
Brand
SAA
Rated Voltage System
66kv
Creepage Distance
up to 2350mm
Core Rod Material
Fiber Glass Core
End Fitting Material
HDG Steel
Delivery Time
3~20days
Transport Package
Carton or Plywood Case
Specification
Customers′ Requirements
Trademark
SAA
Origin
China
HS Code
8546201000
Production Capacity
1000, 000PCS/Year

Product Description

66kv Post Silicone Rubber Insulator for High Voltage Power Station

66kv Post Silicone Rubber Insulator for High Voltage Power Station
66kv Post Silicone Rubber Insulator for High Voltage Power Station
Technical Drawings for Post Insulator 
66kv Post Silicone Rubber Insulator for High Voltage Power Station
66kv Post Silicone Rubber Insulator for High Voltage Power Station
66kv Post Silicone Rubber Insulator for High Voltage Power Station
Technical Specification

Rated
System
Voltage
(
kV)

Section
Length
(mm)

Arcing
Distance
(mm)

Creepage
Distance
(mm)

Specific
Creepage
Distance

 

Specified
Cantilever
Load
(kN)

Specified torsional Load
(kN·m)

Specified
Tensile Load
(kN)

Lightning Impulse
Withstand Voltage
(kV)
Power Frequency
Withstand Voltage
(kV)

Dry

Wet
66 770 ≥600 2250(e)/1820(d) 53.7(e)/43.3(d) 6 4 10 ≥325 175 140
66 970 ≥800 2350 53.7(e)/43.3(d) 10 5 10 450 225 185
66 770 ≥600 2250(e)/1820(d) 53.7(e)/43.3(d) 12.5 6 10 ≥325 175 140
Order Information:
1.Voltage grade; 2.Specified mechanical load; 3.Creepage distance; 4.Power frequency withstand voltage;
5.
Lightning impulse withstand voltage; 6.Insulation distance; 7.Coupling type

Ps. Different design could be supplied as customer requirements

COMPANY PROFILE
    Founded in 1986, SAA Grid Technology Co., Ltd is a national high-tech enterprise and one of the most powerfulpolymer insulator manufacturers in China. We manufacture the following products: 110kV-1000kV polymer long rod insulators, 11kV-230kV polymer line post insulators, 11kV-800kV polymer station post insulators, 27.5kV polymer railway insulators; surge arresters, drop-out fuse cutout, disconnectors and other electrical products.
66kv Post Silicone Rubber Insulator for High Voltage Power Station
66kv Post Silicone Rubber Insulator for High Voltage Power Station
66kv Post Silicone Rubber Insulator for High Voltage Power Station
Factory
66kv Post Silicone Rubber Insulator for High Voltage Power Station
66kv Post Silicone Rubber Insulator for High Voltage Power Station

66kv Post Silicone Rubber Insulator for High Voltage Power Station
66kv Post Silicone Rubber Insulator for High Voltage Power Station
66kv Post Silicone Rubber Insulator for High Voltage Power Station
66kv Post Silicone Rubber Insulator for High Voltage Power Station
66kv Post Silicone Rubber Insulator for High Voltage Power Station
66kv Post Silicone Rubber Insulator for High Voltage Power Station

FAQ
1.Q:What's your main products?
   A:High voltage electrical equipment, including circuit breaker, arrester, insulator, load switch, etc. Low voltage electrical equipment including smart meter, time           switch, etc.

2.Q:Do you have a catalog? Could you send me your catalogue?
    A:Yes, we have a catalogue. Please contact us, we can send you product catalog online or email.

3.Q:Can I get some samples?
   A:Yes, sample order is available for quality check and market test.

4.Q:Can your factory produce according to customer's requirements?
    A:Yes, we can produce different products according to customers' requirements.

5.Q:What's your packing standard?
    A:Usually we use standard cartons for packing or according to customers' requirements.

6.Q:When is the delivery time?
    A:We will arrange shipment within 3-20 days after your payment.

7.Q:Can we visit your company?
    A: Yes, for sure, you are welcome to visit our company.
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ANSI/ESD
OEM/ODM Availability
Yes